ScanMaster User Guide
4.3 PREFIX/SUFFIX CODE
Click the Prefix Code or Suffix Code field so that you can choose characters from the
pop-up window of Grid Control (see Grid Control — Original below).
Prefix Code: None
Suffix Code: By default, [ENTER] or [CR] (Carriage Return) is entered.
Up to eight characters can be chose from the Grid Control. For example, “Barcode_”, and
you will have the string appear in front of the barcode read, like this —
“Barcode_1234567890”.
If "Keyboard Wedge" is selected for interface, the Grid Control will be different and
provide options of Key Type/Key Status. Decide whether or not to apply Key Status when
“Normal Key” is selected for Key Type.