ScannerConfigurationSmartScanManual DOCVersion2.21Thisdocumentisspecificallydesignedfortheusertoprinttwopagespersheetofp
2 Enter Setup Scanner Configuration SmartScan Manual LIST CURRENT SETTINGS Serial Command 9950 List settings regarding Interface, Buzzer, and Scanne
3 Update 1.1 RF AUTO SHUTDOWN (SUSPEND MODE) 1) Read this label to specify the time interval before the scanner enters suspend mode. 2) Read
4 Enter Setup Scanner Configuration SmartScan Manual 1.4.2 SEND DATA Serial Command 9918 Send Data 1.4.3 CLEAR DATA 1) Read the “Clear Data”
5 Update Chapter 1 Bluetooth Settings (1166/1266) 1.5 SET CONNECTION WITH 3666 1) Read this label or the same one at the bottom of the 3666
6 Enter Setup Scanner Configuration SmartScan Manual 1.6.2 BLUETOOTH HID PARAMETERS 1) Read this label to activate Bluetooth HID and select a keyboa
7 Update Chapter 1 Bluetooth Settings (1166/1266) PIN CODE 1) Read this label to specify the PIN code. 2) Read the “Hexadecimal Value” la
8 Enter Setup Scanner Configuration SmartScan Manual CAPITAL LOCK SETTING Serial Command 0002 Serial Command 0003 Auto Detection Capital Lo
9 Update 2.1 GOOD READ NOTIFICATION 2.1.1 BUZZER SETTING Serial Command 0318 Serial Command 0319 <Enable Buzzer> Disable Buzzer 2
10 Enter Setup Scanner Configuration SmartScan Manual Serial Command 0068 Serial Command 0069 Auto Power Off Mode Alternate Mode Serial Comm
11 Update Chapter 2 Reader Settings Serial Command 0338 Serial Command 0339 <400 ms> 800 ms Serial Command 0340 Serial
Copyright © 2005~ 2008 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided u
12 Enter Setup Scanner Configuration SmartScan Manual
13 Update 3.1 KEYBOARD WEDGE PARAMETERS 3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE 1) Read this label to activate Keyboard Wedge and select a keybo
14 Enter Setup Scanner Configuration SmartScan Manual 3.1.2 ALPHABETS LAYOUT Serial Command 0312 Serial Command 0313 <Default Layout>
15 Update Chapter 3 Output Interfaces 3.1.6 ALPHABETS TRANSMISSION Serial Command 0005 Serial Command 0006 Ignore Case <Case-Se
16 Enter Setup Scanner Configuration SmartScan Manual 3.2 RS-232 PARAMETERS 3.2.1 ACTIVATE RS-232 INTERFACE Serial Command 0001 Activate RS-2
17 Update Chapter 3 Output Interfaces 3.2.4 DATA BITS Serial Command 0034 Serial Command 0035 <8 bits> 7 bits 3.2.5 FLOW
18 Enter Setup Scanner Configuration SmartScan Manual 3.3 WAND EMULATION PARAMETERS (1090+/1100/1105/1200) 3.3.1 ACTIVATE WAND EMULATION Serial Comma
19 Update Chapter 3 Output Interfaces 3.3.5 MARGIN TIME Serial Command 0370 Serial Command 0371 5 ms 10 ms Serial Command 037
20 Enter Setup Scanner Configuration SmartScan Manual
21 Update 4.1 SELECT READABLE BARCODES CODABAR Serial Command 0086 Serial Command 0087 <Enable> Disable CODE 39 Serial Comman
VERSION DATE NOTES 2.21 Jan. 02, 2008 Larger setup barcodes 2.20 Nov. 30, 2007 New Word template applied New: 3667 Bluetooth Cradle for 1166
22 Enter Setup Scanner Configuration SmartScan Manual Serial Command 0108 Serial Command 0109 Enable Addon 2 <Disable Addon 2>Serial
23 Update Chapter 4 Symbology Settings INTERLEAVED 25 Serial Command 0082 Serial Command 0083 <Enable> Disable MATRIX 25 S
24 Enter Setup Scanner Configuration SmartScan Manual UPC-A Serial Command 0291 Serial Command 0292 <Enable No Addon> Disable No Addon
25 Update Chapter 4 Symbology Settings 4.2 CODABAR PARAMETERS Serial Command 0086 Serial Command 0087 <Enable> Disable STA
26 Enter Setup Scanner Configuration SmartScan Manual 4.3 CODE 25 PARAMETERS 4.3.1 INDUSTRIAL 25 Serial Command 0080 Serial Command 0081 &l
27 Update Chapter 4 Symbology Settings Serial Command 0210 Serial Command 0211 Max. Length Min. Length Serial Command 0209
28 Enter Setup Scanner Configuration SmartScan Manual CODE LENGTH QUALIFICATION 1) Read the label to enable either Max. /Min. length qualification o
29 Update Chapter 4 Symbology Settings CHECKSUM VERIFICATION Serial Command 0147 Serial Command 0148 Enable <Disable> CH
30 Enter Setup Scanner Configuration SmartScan Manual 4.4 CODE 39 PARAMETERS Serial Command 0074 Serial Command 0075 <Enable> Dis
31 Update Chapter 4 Symbology Settings 4.7 EAN-8 PARAMETERS Serial Command 0098 Serial Command 0099 <Enable No Addon> Disable N
32 Enter Setup Scanner Configuration SmartScan Manual 4.8 EAN-13 PARAMETERS Serial Command 0106 Serial Command 0107 <Enable No Addon>
33 Update Chapter 4 Symbology Settings 4.9 EAN-128 PARAMETERS Serial Command 0104 Serial Command 0105 Enable <Disable> COD
34 Enter Setup Scanner Configuration SmartScan Manual 4.10 MSI PARAMETERS Serial Command 0112 Serial Command 0113 Enable <Disable>
35 Update Chapter 4 Symbology Settings Serial Command 0222 Serial Command 0223 Max. Length Min. Length Serial Command 0221
36 Enter Setup Scanner Configuration SmartScan Manual 4.11 PHARMACODE PARAMETERS 4.11.1 FRENCH PHARMACODE Serial Command 0078 Serial Command 0079
37 Update Chapter 4 Symbology Settings 4.12 PLESSEY PARAMETERS Serial Command 0114 Serial Command 0115 Enable <Disable> CO
38 Enter Setup Scanner Configuration SmartScan Manual 4.13 RSS FAMILY PARAMETERS CODE ID SELECTION Serial Command 0432 Serial Command 0433
39 Update Chapter 4 Symbology Settings CODE ID TRANSMISSION Serial Command 0420 Serial Command 0421 <Enable> Disable APPLIC
40 Enter Setup Scanner Configuration SmartScan Manual 4.14 TELEPEN PARAMETERS Serial Command 0436 Serial Command 0437 Enable <Disabl
41 Update Chapter 4 Symbology Settings 4.15 UPC-A PARAMETERS Serial Command 0291 Serial Command 0292 <Enable No Addon> Disable
CONTENTS RELEASE NOTES ...
42 Enter Setup Scanner Configuration SmartScan Manual 4.16 UPC-E PARAMETERS Serial Command 0092 Serial Command 0093 <Enable No Addon>
43 Update 5.1 CHARACTER SUBSTITUTION 1) Read the label to enable either character substitution by set. 2) Read the “Hexadecimal Value” label on
44 Enter Setup Scanner Configuration SmartScan Manual 5.3.2 SELECT PRE-DEFINED CODE ID Serial Command 9961 Serial Command 9962 Code ID Set 1
45 Update Chapter 5 Data Output Format Serial Command 0261 Serial Command 0268 Matrix 25 MSI Serial Command 0269 Serial Comman
46 Enter Setup Scanner Configuration SmartScan Manual EAN-8 Serial Command 0244 Serial Command 0245 Enable Length Code <Disable Length
47 Update Chapter 5 Data Output Format MSI Serial Command 0248 Serial Command 0249 Enable Length Code <Disable Length Code>
48 Enter Setup Scanner Configuration SmartScan Manual
49 Update 6.1 FORMAT SELECTION 6.1.1 ACTIVATE EDITING FORMATS FORMAT 1 Serial Command 0281 Serial Command 0282 Enable Editing Format 1
50 End Format Programming Scanner Configuration SmartScan Manual 6.2 EDITING FORMAT PARAMETERS 6.2.1 SELECT FORMAT TO CONFIGURE START FORMAT PROGRAMM
51 Update Chapter 6 Data Editing Serial Command 0524 Serial Command 0526 EAN-8 No Addon EAN-8 Addon 2 Serial Command 0528 Serial Co
Scanner Configuration SmartScan Manual 3.1.7 Digits Transmission...
52 End Format Programming Scanner Configuration SmartScan Manual 2) Read the “Decimal Value” label on page 57 for the desired length. 3) Read the
53 Update Chapter 6 Data Editing FIELD 1 SETTING 1) Read the label to divide field by a specified terminating string. 2) Read the “Hexadecim
54 End Format Programming Scanner Configuration SmartScan Manual Serial Command 0558 Divide Field by Field Length … FIELD 3 SETTING 1) Read
55 Update Chapter 6 Data Editing 3) Read the “Validate” label on the same page to complete this setting. Serial Command 0566 Divide Fie
56 End Format Programming Scanner Configuration SmartScan Manual Serial Command 0576 Additional Field 5… 6.2.6 FIELD TRANSMISSION SEQUENCE 1
57 Update DECIMAL SYSTEM DECIMAL Serial Command 9900 Serial Command 9901 0 1 Serial Command 9902 Serial Command
58 Enter Setup Scanner Configuration SmartScan Manual HEXADECIMAL SYSTEM HEXADECIMAL Serial Command 9900 Serial Command 9901 0
59 KEYBOARD WEDGE TABLE 0 1 2 3 4 5 6 7 8 0 F2 SP 0 @ P ` p b 1 INS F3 ! 1 A Q a q c 2 DLT F4 " 2 B R b r d 3 Home
60 Scanner Configuration SmartScan Manual KEY STATUS Serial Command 9930 Serial Command 9931 Add Shift Add Left Ctrl Serial Com
61 SERIAL COMMANDS #@nnnn<CR> Purpose To configure the scanner. Remarks nnnn – the four digits of command parameters. For example, “9952
Scanner Configuration SmartScan Manual 5.3 Code ID Setting ...
62 Scanner Configuration SmartScan Manual For the scanner to change the buzzer frequency to 4 kHz and beep – #@0047<CR> #@////<CR>
63 HOW TO UPGRADE 1166/1266 FIRMWARE You can only upgrade firmware of one scanner at a time. You must remove the battery of each of the rest sca
64 Scanner Configuration SmartScan Manual Enter Setup Download 6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer.
65 Appendix IV Upgrading Firmware HOW TO UPGRADE 3666 FIRMWARE 1) Connect the power supply cord from the 3666 cradle to a proper power outle
66 Scanner Configuration SmartScan Manual 4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in sequ
1 Update ENTER CONFIGURATION MODE Serial Command N/A Enter Setup EXIT CONFIGURATION MODE UPDATE SETTINGS Serial Command 9999 Update EXIT WITH
Komentáře k této Příručce